Modes

There are 3 operating modes for the LabRat:

  • Random Retrigger - This mode will randomly trigger the output within a set time range and after a set delay.
  • Delayed Trigger - This mode will delay the input trigger by a set time before triggering the output.
  • Motion - This mode disables the onboard input and uses the Passive Infrared (PIR) sensor to trigger the output with or without a delay.

Random Retrigger

The first mode is the Random Retrigger mode. This mode will randomly trigger the output within a set time range and after a set delay.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before starting the randomized timer.
  • Range - This is the maximum time in seconds the LabRat will set the randomized timer to.

Examples

  • Delay - 0, Range - 5
    • This will trigger the output between 0 and 5 seconds randomly on a loop.
  • Delay - 5, Range - 10
    • This will wait 5 seconds before starting the random timer and then trigger the output between that moment and 10 seconds randomly on a loop.
  • Delay - 0, Range - 0
    • This will trigger the output immediately and then again immediately on a loop. (very annoying)
  • Delay - 5, Range - 0
    • This will trigger the output every 5 seconds on a loop.

Delayed Trigger

The second mode is the Delayed Trigger mode. This mode will delay the input trigger by a set time before triggering the output.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before triggering the output after the input is triggered.
  • Reset - This is the time in seconds the LabRat will wait before allowing the input to trigger the output again.

Examples

  • Delay - 0, Reset - 5
    • This will trigger the output immediately and then wait 5 seconds before allowing the input to trigger the output again.
  • Delay - 5, Reset - 10
    • When the input is triggered, the LabRat will wait 5 seconds before triggering the output and then wait 10 seconds before allowing the input to trigger the output again.

Motion

The third mode is the Motion mode. This mode disables the onboard input and uses the Passive Infrared (PIR) sensor to trigger the output with or without a delay.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before triggering the output after the PIR sensor is triggered.
  • Reset - This is the time in seconds the LabRat will wait before allowing the PIR sensor to trigger the output again.

Examples

  • Delay - 0, Reset - 5
    • This will trigger the output immediately and then wait 5 seconds before allowing the PIR sensor to trigger the output again.
  • Delay - 5, Reset - 10
    • When the PIR sensor is triggered, the LabRat will wait 5 seconds before triggering the output and then wait 10 seconds before allowing the PIR sensor to trigger the output again.