Modes

There are 3 operating modes for the LabRat:

  • Random Retrigger - This mode will randomly trigger the output within a set time range and after a set delay.
  • Delayed Trigger - This mode will delay the input trigger by a set time before triggering the output.
  • Motion - This mode disables the onboard input and uses the Passive Infrared (PIR) sensor to trigger the output with or without a delay.

Random Retrigger​

The first mode is the Random Retrigger mode. This mode will randomly trigger the output within a set time range and after a set delay.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before starting the randomized timer.
  • Range - This is the maximum time in seconds the LabRat will set the randomized timer to.

Examples​

  • Delay - 0, Range - 5
    • This will trigger the output between 0 and 5 seconds randomly on a loop.
  • Delay - 5, Range - 10
    • This will wait 5 seconds before starting the random timer and then trigger the output between that moment and 10 seconds randomly on a loop.
  • Delay - 0, Range - 0
    • This will trigger the output immediately and then again immediately on a loop. (very annoying)
  • Delay - 5, Range - 0
    • This will trigger the output every 5 seconds on a loop.

Delayed Trigger​

The second mode is the Delayed Trigger mode. This mode will delay the input trigger by a set time before triggering the output.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before triggering the output after the input is triggered.
  • Reset - This is the time in seconds the LabRat will wait before allowing the input to trigger the output again.

Examples​

  • Delay - 0, Reset - 5
    • This will trigger the output immediately and then wait 5 seconds before allowing the input to trigger the output again.
  • Delay - 5, Reset - 10
    • When the input is triggered, the LabRat will wait 5 seconds before triggering the output and then wait 10 seconds before allowing the input to trigger the output again.

Motion​

The third mode is the Motion mode. This mode disables the onboard input and uses the Passive Infrared (PIR) sensor to trigger the output with or without a delay.

There are two settings for this mode:

  • Delay - This the time in seconds the LabRat will wait before triggering the output after the PIR sensor is triggered.
  • Reset - This is the time in seconds the LabRat will wait before allowing the PIR sensor to trigger the output again.

Examples​

  • Delay - 0, Reset - 5
    • This will trigger the output immediately and then wait 5 seconds before allowing the PIR sensor to trigger the output again.
  • Delay - 5, Reset - 10
    • When the PIR sensor is triggered, the LabRat will wait 5 seconds before triggering the output and then wait 10 seconds before allowing the PIR sensor to trigger the output again.